July 7, 2026 | Burleson, TX
Customer renewed their Level 2 Maintenance Agreement. We completed our comprehensive 25-point maintenance inspection, checked all operating levels and system components, and verified everything was within proper specifications. The system is operating efficiently and cooling properly.
July 6, 2026 | Crowley, TX
Customer called because their thermostat was not working properly. We replaced the thermostat, tested the system, and confirmed everything is operating correctly.
July 2, 2026 | Richardson, TX
Customer called because one of their properties was not cooling properly. We found a failed capacitor and contactor, replaced both components, and tested the system to ensure everything is operating correctly. The unit is now running and cooling properly.
July 2, 2026 | Arlington, TX
Customer called because they suspected a bad capacitor. We inspected the system, confirmed the capacitor had failed, and replaced it. After testing the unit, we verified everything is running properly and cooling as it should.
July 1, 2026 | Fort Worth, TX
Customer called because their home was not cooling properly. We found a refrigerant leak at the indoor coil and recharged the system with refrigerant. After completing the service, we verified the system was operating properly and cooling again.
July 1, 2026 | Arlington, TX
Customer scheduled a two-system A/C maintenance. During the inspection, we found one condenser needed a new fan motor, so we replaced the fan motor and installed a new capacitor. We also replaced the air filters, tested both systems, and confirmed everything is running properly and cooling as it should.
June 30, 2026 | Cleburne, TX
Customer called because their home was not cooling properly. We found the indoor fan was not running due to the blower motor overheating, which was caused by a dirty air filter restricting airflow. We replaced the filter, verified the blower motor was operating properly, and confirmed the system is now ...
June 29, 2026 | Arlington, TX
The customer brought in a window unit that was not cooling and asked us to inspect it. After testing the unit, we found the fan motor had failed. Due to the cost of the repair exceeding the value of the unit, we recommended replacing it and disposed of the old ...
June 29, 2026 | Springtown, TX
We installed a 3-ton heat pump, but at the time of installation there was no incoming power, so we had to return once power was available. During the startup, we found a faulty TXV at the air handler, replaced it, recharged the system with refrigerant, and verified everything is now ...
June 28, 2026 | Burleson, TX
Customer called because the home was not maintaining the set temperature. We found the indoor coil frozen upon arrival and the outdoor condenser dirty. We cleaned the condenser, checked the amp draw on the compressor, fan motor, and blower motor, and confirmed the system is now operating properly.
June 26, 2026 | Burleson, TX
Customer requested a maintenance inspection before moving into their new home. We thoroughly inspected the system, including the wiring, safety switches, drains, filters, and indoor coil, and found everything to be clean and in good working condition. The system is operating properly and is ready for the new homeowners.
June 26, 2026 | Fort Worth, TX
Customer called because their A/C system was not cooling properly. We went out and inspected the unit and found that the transformer had tripped, causing the system to stop operating. We reset the transformer, checked the system operation, and confirmed everything is running properly and cooling as it should.
Total: 573