June 12, 2026 | Fort Worth, TX
Customer called to schedule a service visit because their system was not cooling properly. Upon inspection, we found that the fan wire was connected to the incorrect terminal on the run capacitor. We corrected the wiring, tested the system, and confirmed that everything is operating properly and cooling as it ...
June 12, 2026 | Joshua, TX
Customer called because water was pooling from the secondary drain line onto the back porch. Upon inspection, we found that the drain line was clogged and cleared the blockage. We tested the system, confirmed proper drainage, and verified that the unit is cooling properly with no further water pooling.
June 9, 2026 | Burleson, TX
Customer called and reported that their mini-split system was not cooling properly. Our technician inspected the unit and found that it was completely out of refrigerant, indicating a leak in the system. We recommended inspecting the flare fittings for cracks or damage to locate the source of the leak.
June 8, 2026 | Crowley, TX
Customer called to schedule a maintenance, and our technician performed a full system inspection. Everything was operating properly at the time of service. We did recommend cleaning the blower wheel and blower housing due to the amount of debris buildup to help maintain system efficiency and airflow.
June 8, 2026 | Burleson, TX
Customer called and reported that their AC unit had frozen over. Our technician found that the system was low on refrigerant and that the outdoor compressor was struggling to start. We cleaned the outdoor coil and added two pounds of refrigerant to restore operation. The system is now up and ...
June 8, 2026 | Fort Worth, TX
Customer called and reported that the breaker would trip each time the thermostat called for cooling. Our technician performed a complete system inspection and maintenance, and all HVAC equipment was found to be operating properly. At this time, we believe the issue is related to an electrical problem outside of ...
June 7, 2026 | Midlothian, TX
Customer called and reported that their AC was not running. Our technician inspected the system and found that the capacitor had failed. We replaced the faulty capacitor, tested the unit, and confirmed that the system is now operating properly and cooling as it should.
June 5, 2026 | Burleson, TX
Customer was contacted to schedule their routine maintenance as part of their maintenance agreement. Our technician completed a full system inspection and found everything to be operating properly. We checked all wiring, safety switches, refrigerant levels, and capacitor, inspected the coil, and cleaned the outdoor condenser to help keep the ...
June 5, 2026 | Burleson, TX
Customer called and requested that we inspect their AC system. Our technician found that the system was overcharged with refrigerant and corrected the charge to the proper level. We also discovered a blockage affecting the indoor blower and addressed the issue. The contactor and condenser fan motor were inspected and ...
June 3, 2026 | Fort Worth, TX
Customer's existing compressor had failed and needed to be replaced. Our technicians installed a new 5-ton heat pump compressor, tested the system, and verified that everything is operating properly and efficiently.
June 2, 2026 | Fort Worth, TX
Customer called and reported that their downstairs AC unit was not coming on. Our technician inspected the system and found that it was low on refrigerant due to a leak in the indoor coil. We recommended replacing the indoor coil to properly repair the issue and restore reliable system operation.
May 30, 2026 | Midlothian, TX
Customer reported that the system was not operating properly. Upon inspection, we found a failed indoor blower motor. We replaced the blower motor with a new one and checked the amp draw on the compressor, condenser fan motor, and blower motor to ensure proper operation. The system is now running ...
May 29, 2026 | Fort Worth, TX
Customer reported that their thermostat was not coming on. We performed maintenance on both HVAC systems. One unit was operating properly with no issues found. On the second unit, we found the overflow safety switch had tripped due to a clogged secondary drain line. We cleared the drain line and ...
Total: 573