July 31, 2026 | Burleson, TX
Customer called because their system was shutting off due to the drain line safety switch. We found the primary drain line was backed up, causing water to drain through the secondary line. We cleared the blockage and restored proper drainage. The system is now back up and running properly.
July 30, 2026 | Fort Worth, TX
Customer called because their home was not cooling properly. We found a failed outdoor capacitor, a leaking evaporator coil, and a compressor drawing excessive startup amperage. We replaced the capacitor, replaced the leaking evaporator coil, and installed a soft start to help protect the compressor. The system is now running ...
July 29, 2026 | Burleson, TX
Customer called because their home was not cooling properly. Our team replaced a faulty capacitor and performed a thorough leak inspection, discovering a leak at the indoor evaporator coil. After completing the necessary service, the system is back up and cooling comfortably again.
July 29, 2026 | Burleson, TX
Customer called because their system was not cooling. Our technicians found the compressor was pulling excessive amperage, causing multiple components to overheat and fail. We provided repair and replacement options, and the customer chose to move forward with a new York system installation.
July 26, 2026 | Burleson, TX
The customer called because the home was not cooling. Upon inspection, we found the connectors and control components were shorted and had sustained burn damage. The air handler is obsolete, and replacement parts are no longer available. Due to the age and condition of the system, we recommended replacing the ...
July 26, 2026 | Joshua, TX
The customer called because the home was not cooling. We found a failed capacitor and replaced it with a Turbo capacitor. We also cleaned the outdoor condenser coil. The system is now operating and cooling properly.
July 24, 2026 | Burleson, TX
The customer requested a duct inspection and A/C maintenance. We found the ductwork and indoor air handler need cleaning. The outdoor compressor has high startup amps, and we recommended a soft start kit. The system is also struggling to cool due to a flooding TXV.
July 23, 2026 | Burleson, TX
We contacted the customer to schedule their summer maintenance as part of their maintenance agreement. We inspected the upstairs system and found it operating properly. All components were within normal operating range, and the system is cooling as it should.
July 23, 2026 | Arlington, TX
The customer is part of our yearly maintenance agreement, so we performed their scheduled maintenance. All system components were operating within normal range. We noted high compressor locked rotor (LRA) startup amps and recommended a soft start kit to reduce startup load and help extend compressor life. The system is ...
July 23, 2026 | Arlington, TX
Customer chose to upgrade to a new 14 SEER Goodman gas system. We installed a complete system, including a new furnace, evaporator coil, condenser, and thermostat. The installation was completed successfully, and the system is operating properly and cooling efficiently.
July 23, 2026 | Arlington, TX
Customer contacted us for an estimate on a new HVAC system. After reviewing their home's needs, we provided a quote for a new Goodman 14 SEER gas system. The customer chose to move forward with the installation, and we installed a new furnace, evaporator coil, outdoor condenser, and thermostat. The new ...
July 22, 2026 | Burleson, TX
We contacted the customer to schedule their routine maintenance as part of their maintenance agreement. Both systems were inspected and are operating well. One system was found to be low on refrigerant, and a leak search confirmed the evaporator coil is leaking. We recommended replacing the evaporator coil. Aside from ...
July 22, 2026 | Fort Worth, TX
The customer called because the home was not cooling. We found the outdoor fan was not running due to a failed capacitor, which was reading zero on all terminals. We also found the compressor had high locked rotor (LRA) startup amps. We replaced the capacitor and recommended installing a soft ...
July 22, 2026 | Cleburne, TX
Customer called because their system was not cooling properly. We found that the outdoor condenser fan motor had seized and was no longer operating correctly. We replaced the motor, and the system is now back up and cooling properly.
Total: 573