July 22, 2026 | Cleburne, TX
The customer scheduled a service call because the system was not cooling properly. We found a communication error on the 24-volt side of the air handler. We tightened all electrical connections and verified power was properly restored to all components. The system is now operating and cooling correctly. If the ...
July 22, 2026 | Burleson, TX
The customer called because the home was not cooling. We found the fan capacitor had failed, preventing the outdoor fan from operating. We replaced the capacitor, tested the system, and verified that it is now operating and cooling properly.
July 21, 2026 | Crowley, TX
The homeowner called because their AC system was freezing up. Our inspection found a severely clogged evaporator coil, a weak outdoor capacitor, and a badly worn contactor. Due to the age and condition of the system, the homeowner chose to upgrade to a new 4-ton Goodman upflow system. We completed ...
July 21, 2026 | Burleson, TX
As part of our maintenance agreement program, we contacted the customer to schedule their routine service. During the inspection, we found the system was low on refrigerant due to a leak in the evaporator coil. The indoor unit also needs to be cleaned. All other components were operating properly at ...
July 20, 2026 | Arlington, TX
The customer called because their system was not cooling. We found the outdoor control board had proper voltage but failed to power on, preventing communication with the indoor unit and thermostat. We restored the system to normal operation and grounded the compressor windings. We recommended replacing the control board if ...
July 20, 2026 | Burleson, TX
The customer called because their home was not cooling. We found the outdoor unit had a failed capacitor and replaced it. After testing the system, everything was operating and cooling properly.
July 16, 2026 | Fort Worth, TX
Customer's drain pan had cracked and needed to be replaced. We installed a new drain pan, cleaned both the indoor evaporator coil and the outdoor condenser coil, and tested the system. Everything is now operating properly and draining as it should.
July 14, 2026 | Midlothian, TX
We contacted the customer to perform their routine maintenance as part of their maintenance agreement. Both the upstairs and downstairs systems were operating properly. We found high startup amp draw on the outdoor compressors, so we installed two soft start kits to reduce startup amps and replaced a capacitor as ...
July 14, 2026 | Fort Worth, TX
We were called out to the business because the system was not draining properly. We found the drain line was missing a P-trap, so we installed one to ensure proper drainage. The system is now operating and draining as it should.
July 11, 2026 | Fort Worth, TX
The customer called because the thermostat showed the temperature was rising. We found the condensate drain line was clogged, causing the safety switch to shut the system off. We cleared the drain line and P-trap, and the system is now running and cooling properly.
July 10, 2026 | Grand Prairie, TX
As part of our maintenance agreement program, we contacted the customer to schedule their routine maintenance. During the inspection, we found the system was low on refrigerant. We added the necessary refrigerant, and the system is now operating and cooling properly. All other components were working as expected.
July 10, 2026 | Alvarado, TX
The customer contacted us for a quote on a new mini-split system because their current unit was no longer cooling properly. We found the outdoor unit had a failed control board and compressor. The customer chose to move forward with the replacement, and we installed the new mini-split system along ...