August 28, 2026 | Fort Worth, TX
The customer contacted us because their home was not cooling properly. Upon arrival, we found that the system had lost 24-volt power due to a backed-up condensate drain line. We cleared the drain line and cleaned the P-trap under the sink, which restored power to the system. We tested the ...
August 28, 2026 | Fort Worth, TX
Our customer called because their home was not cooling properly. During our visit, we found that the system’s capacitor had failed. We replaced it with a reliable Turbo 200X capacitor and tested the system to make sure everything was working properly. The home is now cooling comfortably and the ...
August 27, 2026 | Keller, TX
Customer called because the system was not cooling. We found the system was low on refrigerant and added Freon. The system is now cooling properly. We also provided an estimate for replacing the evaporator coil and drain pan.
July 31, 2026 | Burleson, TX
Customer called because their system was shutting off due to the drain line safety switch. We found the primary drain line was backed up, causing water to drain through the secondary line. We cleared the blockage and restored proper drainage. The system is now back up and running properly.
July 30, 2026 | Fort Worth, TX
Customer called because their home was not cooling properly. We found a failed outdoor capacitor, a leaking evaporator coil, and a compressor drawing excessive startup amperage. We replaced the capacitor, replaced the leaking evaporator coil, and installed a soft start to help protect the compressor. The system is now running ...
July 29, 2026 | Burleson, TX
Customer called because their home was not cooling properly. Our team replaced a faulty capacitor and performed a thorough leak inspection, discovering a leak at the indoor evaporator coil. After completing the necessary service, the system is back up and cooling comfortably again.
July 29, 2026 | Burleson, TX
Customer called because their system was not cooling. Our technicians found the compressor was pulling excessive amperage, causing multiple components to overheat and fail. We provided repair and replacement options, and the customer chose to move forward with a new York system installation.
July 26, 2026 | Burleson, TX
The customer called because the home was not cooling. Upon inspection, we found the connectors and control components were shorted and had sustained burn damage. The air handler is obsolete, and replacement parts are no longer available. Due to the age and condition of the system, we recommended replacing the ...
July 26, 2026 | Joshua, TX
The customer called because the home was not cooling. We found a failed capacitor and replaced it with a Turbo capacitor. We also cleaned the outdoor condenser coil. The system is now operating and cooling properly.
July 24, 2026 | Burleson, TX
The customer requested a duct inspection and A/C maintenance. We found the ductwork and indoor air handler need cleaning. The outdoor compressor has high startup amps, and we recommended a soft start kit. The system is also struggling to cool due to a flooding TXV.
July 23, 2026 | Burleson, TX
We contacted the customer to schedule their summer maintenance as part of their maintenance agreement. We inspected the upstairs system and found it operating properly. All components were within normal operating range, and the system is cooling as it should.
July 23, 2026 | Arlington, TX
The customer is part of our yearly maintenance agreement, so we performed their scheduled maintenance. All system components were operating within normal range. We noted high compressor locked rotor (LRA) startup amps and recommended a soft start kit to reduce startup load and help extend compressor life. The system is ...